LINEEYE CO., LTD.
Firmware Version History for LE-3500/LE-2500/LE-1500
Version. 1.11 Mar 6, 2015
- Number of pre-registered data tables are increased to 160.(before 16 tables)
- Able to set maximum 2 characters as frame end of ASYCN
- Prohibits Simulation and BERT function
- Adds setting information of idle time and time stamp on the top of print-out data.
- Corrects the miner bug on remote monitor proceeding for USB connection.
[ detail ]
Version. 1.10 Jun 4, 2013
- Correct the bug that LE-1500 cannot access to the 8G byte CF card.
Version. 1.09 Mar 13, 2013
- Correct the bug on test pattern when "Flow Control: ON" at RTX/CTS for BERT test.
- Correct the bug on the CT and EXT value of logic analyzer signal. (If using Version1.07 or 1.08)
Version. 1.08 Jan 22, 2013
- Able to transmit BREAK by pressing [X] key in the ASYNK manual simulation.
- Add file size 16Mbyte in the Auto save function.
- Change initial value of time stamp from OFF(no record) to HMS(hr/min/sec).
<LE-3500 only>
- Add SEND BRK command in the PROGRAM simulation.
[ detail ]
Version. 1.07 Dec 25, 2012
- Support RTS/CTS flow control for BERT.
- Add information of analyzer in the measured data.
Information of analyzer and date of measurement will be added in front of text conversion data or print-out data.
- Improve timing of accessing to the CF card.
- Change the character code display of EBCDIC and EBCDIK to be same as LE-8200.
- Change the specification of frame translation to be same as LE-8200.
- Correct a minor bug of position of abort mark "A" in HDLC packet translation display.
- Correct a minor bug of trigger transmission process when trigger condition is satisfied.
- Improve a AR clock extraction circuit to detect the abort of NRZI format on RS-485 HDLC.
- Correct a bug of clock pole inversion setting when using OP-SB5G/5GL.
- Reverse a position of "NS" and "NR"in the title of LrLAP text conversion.
- Correct a bug of incorrect timing of bit on infrared ASK monitored data when using OP-SB6GL.
<LE-3500 only>
- Support Modbus protocol (Modbus-ASCII, Modbus-RTU)
- Correct a bug of SPI simulation when using OP-SB5G/5GL. It stopped simulating when satisfying the trigger condition.
[ detail ]
Version. 1.06 Apr 2, 2012
- Support bigger capacity of CF card.
Max 8G byte for LE-3500 → Max 16G byte
Max 2G byte for LE-2500 → Max 8G byte
- Improve the AR clock extracted circuit for HDLC NRZI format.
- Able to transmit continuously without SS signal rising or falling if setting "0" on Clock phase.
- Change SDI to "1" at the timing of SCK etc after sending the last bit in Slave simulation.
[ detail ]
Version. 1.05 Sep 14, 2010
- Correct the bug that analyzer measures data in duplicate when speed is
more than 500Kbps.
[ detail ]
Version. 1.04 Apr 9, 2010
- Add the function which makes the external triger output active.
- Add the settings for "OP-SB5GL" in the "INTERFACE" setting menu.
- Add the speed of 50Kbps, 200Kbps, 417Kbps for I2C master simulation.
- Correct the bug of incomplete bit in the SPI slave simulation.
- Change the beginning point to start the SPI slave simulation repeat mode as CS falling.
- Add the inter lock for starting measurement when TTL/IrDA pots are not connected.
- Strengthen the self-check function.
- Correct the miner bug of firmware loader.
[ detail ]
Version. 1.03 Sep 17, 2009
- Add a display mode for ASYNC frame per a time stamp
- Support monitoring/simulating SPI protocol (need OP-SB5G)
- Add the function for receiving/transmitting Simulation programs to a PC efficiently.
- Correct miner bug of changing display code when turning of the power.
- Correct the bug that “Invert” in the “Interface” on Simulation mode does not work.
- Fix the calculation process of baud rate clock.
[ detail ]
Version. 1.02 Apr 28, 2009
- Add the function of time differences for timestamp (H/M/S, M/S/10ms) in the translation display mode. (Press [SHIFT]+[TIME/COUNT] to change the display mode. Cannot change the display mode during the measurement.
- Fix the problem of asynchronous in the BERT test pattern 63.
- Fix the problem of cursor key process in the file save setting screen.
- Add the function of battery diagnosis in the self diagnosis function. (Press [1]+[D] while turning on the power.)
[ detail ]
Version. 1.00
LE-3500/2500 released